Centrex 1000 Specifications
| |
|
|
| Composting Capacity |
Weekend & Vacation Use |
5-7 people |
| |
|
|
| Electrical |
Max Amps (with heater on)
Fan Watts (required hookup)
Heater Watts (when thermostat switches it on)
Average Power Use in Watts (heater on ½ time) |
2.4 Amps
30 Watts required
250 Watts
150 Watts |
| |
|
|
| Unit Dimensions (inches) |
Height (unit only)
Depth (unit only)
Width (unit only)
Width required to turn handle |
27½
26¼
31¼
35½ |
| |
|
|
| Vent and Drain |
Vent Pipe
Drain (hookup optional but recommended for heavy use) |
2" Central Vac. Tubing
1" |
| |
|
|
| Weights (lbs) |
Product Weight/ Shipping Weight
|
50/95 |
| |
|
|
| Shipping Carton Dimensions (inches) |
Width
Length
Height |
27
35
29½ |
| |
|
|
| Rough-in Dimensions (inches) |
Depth required to remove drawer
Height to top of waste
inlet
Vent outlet center distance from rear/left side
Waste inlet diameter (including flange)
Height to center or top of vent outlet assembly |
44
30¾
12/11
3" DWV
21¾ |
| |
|
|
| Click on diagram to enlarge |
 |
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.
|
Centrex 1000 NE Specifications
| |
|
|
| Composting Capacity |
Weekend & Vacation Use |
4-6 people |
| |
|
|
| Electrical |
Max Amps (with heater on)
Fan Watts (optional hookup)
Heater Watts (when thermostat switches it on)
Average Power Use in Watts (heater on ½ time) |
NA
1.4 Watts
NA
NA |
| |
|
|
| Unit Dimensions (inches) |
Height (unit only)
Depth (unit only)
Width (unit only)
Width required to turn handle |
27½
26¼
31¼
35½ |
| |
|
|
| Vent and Drain |
Vent Pipe
Drain (hookup required for all uses)
|
4"
1" |
| |
|
|
| Weights (lbs) |
Product Weight/ Shipping Weight
|
45/90 |
| |
|
|
| Shipping Carton Dimensions (inches) |
Width
Length
Height |
27
35
29½ |
| |
|
|
| Rough-in Dimensions (inches)
|
Depth required to remove drawer
Height to top of waste
inlet
Vent outlet center distance from rear/left side
Waste inlet diameter (including flange)
Height to center or top of vent outlet assembly |
44
30¾
12/11
3" DWV
31 |
| |
|
|
| Click on diagram to enlarge |
 |
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.
|
Centrex 1000 AC/DC Specifications
| |
|
|
| Composting Capacity |
Weekend & Vacation Use |
5-7 or 4-6 people |
| |
|
|
| Electrical |
Max Amps (with heater on)
Fan Watts (required or optional hookup)
Heater Watts (when thermostat switches it on)
Average Power Use in Watts (heater on ½ time) |
3.3 or 0.28 Amps
30 required or 2.4 optional
350
200 |
| |
|
|
| Unit Dimensions (inches) |
Height (unit only)
Depth (unit only)
Width (unit only)
Width required to turn handle |
28
27
45½
49
|
| |
|
|
| Vent and Drain |
Vent Pipe
Drain (hookup required for all uses) |
2" and 4"
1"
|
| |
|
|
| Weights (lbs) |
Product Weight/ Shipping Weight
|
108/129 |
| |
|
|
| Shipping Carton Dimensions (inches) |
Width
Length
Height |
28½
47
36 |
| |
|
|
| Rough-in Dimensions (inches) |
Depth required to remove drawer
Height to top of waste
inlet
Vent outlet center distance from rear/left side
Waste inlet diameter (including flange)
Height to center or top of vent outlet assembly |
44
30¾
12/11
3" DWV
both 21¾ and 31 |
| |
|
|
| Click on diagram to enlarge |
|
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.
|
Centrex 2000 Specifications
| |
|
|
| Composting Capacity |
Residential & Continuous Use
Weekend & Vacation Use |
4-6 people
7-9 people |
| |
|
|
| Electrical |
Max Amps (with heater on)
Fan Watts (required hookup)
Heater Watts (when thermostat switches it on)
Average Power Use in Watts (heater on ½ time) |
3.6 Amps
30 Watts Required
370 Watts
200 Watts |
| |
|
|
| Unit Dimensions (inches) |
Height
Depth
Width (unit only)
Width required to turn handle |
28
27
45½
49 |
| |
|
|
| Vent and Drain |
Vent Pipe
Drain (hookup optional but recommended for heavy use) |
2" Central Vac. Tubing
1"
|
| |
|
|
| Weights (lbs) |
Product Weight/ Shipping Weight
|
97/118 |
| |
|
|
| Shipping Carton Dimensions (inches) |
Width
Length
Height |
28½
47
30 |
| |
|
|
| Rough-in Dimensions (inches) |
Depth required to remove drawer
Height to top of waste
inlet
Vent outlet center distance from rear/left side
Waste inlet diameter (including flange)
Height to center or top of vent outlet assembly |
45
31
11/12
3" DWV
23½ |
| |
|
|
| Click on diagram to enlarge |
|
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.
|
Centrex 2000 NE Specifications
| |
|
|
| Composting Capacity |
Residential & Continuous Use
Weekend & Vacation Use |
3-5 people
6-8 people |
| |
|
|
| Electrical |
Max Amps (with heater on)
Fan Watts (optional hookup)
Heater Watts (when thermostat switches it on)
Average Power Use in Watts |
NA
1.4 Watts
NA
NA |
| |
|
|
| Unit Dimensions (inches) |
Height
Depth
Width (unit only)
Width required to turn handle |
26½
26½
45½
49 |
| |
|
|
| Vent and Drain |
Vent Pipe
Drain (hookup required for all uses) |
4"
1" |
| |
|
|
| Weights (lbs) |
Product Weight/ Shipping Weight
|
87/108 |
| |
|
|
| Shipping Carton Dimensions (inches) |
Width
Length
Height |
28½
47
30 |
| |
|
|
| Rough-in Dimensions (inches) |
Depth required to remove drawer
Height to top of waste
inlet
Vent outlet center distance from rear/left side
Waste inlet diameter (including flange)
Height to center or top of vent outlet assembly |
45
29½
11/12
3" DWV
32 |
| |
|
|
| Click on diagram to enlarge |
|
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.
|
Centrex 2000 AC/DC Specifications
| |
|
|
| Composting Capacity |
Residential & Continuous Use
Weekend & Vacation Use |
4-6 or 3-5 people
7-9 or 6-8 people |
| |
|
|
| Electrical |
Max Amps (with heater on)
Fan Watts (required or optional hookup)
Heater Watts (when thermostat switches it on)
Average Power Use in Watts (heater on ½ time) |
3.6 Amps or NA
30 Required or 2.4 Optional
370 or NA
200 or 3.4 |
| |
|
|
| Unit Dimensions (inches) |
Height
Depth
Width (unit only)
Width required to turn handle |
28
27
45½
49 |
| |
|
|
| Vent and Drain |
Vent Pipe
Drain (hookup required for all uses) |
2" Central Vac. Tubing
1"
|
| |
|
|
| Weights (lbs) |
Product Weight/ Shipping Weight
|
103/124 |
| |
|
|
| Shipping Carton Dimensions (inches) |
Width
Length
Height |
28½
47
36 |
| |
|
|
| Rough-in Dimensions (inches) |
Depth required to remove drawer
Height to top of waste
inlet
Vent outlet center distance from rear/left side
Waste inlet diameter (including flange)
Height to center or top of vent outlet assembly |
45
31
11/12
3" DWV
both 23½ and 32 |
| |
|
|
| Click on diagram to enlarge |
|
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.
|
Centrex 3000 Specifications
| |
|
|
| Composting Capacity |
Residential & Continuous Use
Weekend & Vacation Use |
6-8 people
10-12 people |
| |
|
|
| Electrical |
Max Amps (with heater on)
Fan Watts (required hookup)
Heater Watts (when thermostat switches it on)
Average Power Use in Watts (heater on ½ time) |
3.6 Amps
30 Watts Required
370 Watts
215 Watts |
| |
|
|
| Unit Dimensions (inches) |
Height
Depth
Width (including collection housing 13½) |
30¼
27½
71
|
| |
|
|
| Vent and Drain |
Vent Pipe
Drain (hookup required in all installations) |
2" Central Vac. Tubing
1"
|
| |
|
|
| Weights (lbs) |
Product Weight/ Shipping Weight
|
102/172 |
| |
|
|
| Shipping Carton Box 1 Dimensions (inches) |
Width
Length
Height |
28
61
33½ |
| |
|
|
| Shipping Carton Box 2 Dimensions (inches) |
Width
Length
Height |
16
24
23 |
| |
|
|
| Rough-in Dimensions (inches) |
Depth required to remove drawer
Height to top of waste
inlet
Vent outlet center distance from rear/left side
Waste inlet diameter (including flange)
Height to center or top of vent outlet assembly |
45½
32½
24/37¼
3" DWV
24¾ |
| |
|
|
| Click on diagram to enlarge |
|
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.
|
Centrex 3000 NE Specifications
| |
|
|
| Composting Capacity |
Residential & Continuous Use
Weekend & Vacation Use |
5-7 people
8-10 people |
| |
|
|
| Electrical |
Max Amps (with heater on)
Fan Watts (optional hookup)
Heater Watts (when thermostat switches it on)
Average Power Use in Watts |
NA
2.4 Watts
NA
NA |
| |
|
|
| Unit Dimensions (inches) |
Height
Depth
Width (including collection housing 13½) |
29¼
27½
71
|
| |
|
|
| Vent and Drain |
Vent Pipe
Drain (hookup required in all installations) |
4"
1" |
| |
|
|
| Weights (lbs) |
Product Weight/ Shipping Weight
|
88/164 |
| |
|
|
| Shipping Carton Box 1 Dimensions (inches) |
Width
Length
Height |
28
60½
33 |
| |
|
|
| Shipping Carton Box 2 Dimensions (inches) |
Width
Length
Height |
16
24
23 |
| |
|
|
| Rough-in Dimensions (inches) |
Depth required to remove drawer
Height to top of waste
inlet
Vent outlet center distance from rear/left side
Waste inlet diameter (including flange)
Height to center or top of vent outlet assembly |
45½
31½
19¼/37¾
3" DWV
33 (top) |
| |
|
|
| Click on diagram to enlarge |
|
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.
|
Centrex 3000 AC/DC Specifications
| |
|
|
| Composting Capacity |
Residential & Continuous Use
Weekend & Vacation Use |
7-8 or 5-6 people
10-12 or 8-10 people |
| |
|
|
| Electrical |
Max Amps (with heater on)
Fan Watts (required or optional hookup)
Heater Watts (when thermostat switches it on)
Average Power Use in Watts (heater on ½ time) |
3.6 Amps or NA
30 Required or 2.4 Optional
370 or NA
215 or 3.4 |
| |
|
|
| Unit Dimensions (inches) |
Height
Depth
Width (including collection housing 13½) |
30¼
27½
71 |
| |
|
|
| Vent and Drain |
Vent Pipe
Drain (hookup required for all uses) |
2" Central Vac. Tubing and 4"
1"
|
| |
|
|
| Weights (lbs) |
Product Weight/ Shipping Weight
|
107/194 |
| |
|
|
| Shipping Carton Box 1 Dimensions (inches) |
Width
Length
Height |
28
61
37 |
| |
|
|
| Shipping Carton Box 2 Dimensions (inches) |
Width
Length
Height |
16
24
23 |
| |
|
|
| Rough-in Dimensions (inches) |
Depth required to remove drawer
Height to top of waste
inlet
Vent outlet center distance from rear/left side
Waste inlet diameter (including flange)
Height to center or top of vent outlet assembly |
45½
32½
Both 24/37¾ and 19¼/37¾
3" DWV
both 24¾ and 33 |
| |
|
|
| Click on diagram to enlarge |
|
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.
|
|