Centrex 1000 Specifications

     
Composting Capacity Weekend & Vacation Use 5-7 people
     
Electrical Max Amps (with heater on)

Fan Watts (required hookup)

Heater Watts (when thermostat switches it on)

Average Power Use in Watts (heater on ½ time)
2.4 Amps

30 Watts required

250 Watts


150 Watts
     
Unit Dimensions (inches) Height (unit only)
Depth (unit only)
Width (unit only)
Width required to turn handle
27½
26¼
31¼
35½
     
Vent and Drain Vent Pipe

Drain (hookup optional but recommended for heavy use)
2" Central Vac. Tubing

1"
     
Weights (lbs) Product Weight/ Shipping Weight
50/95
     
Shipping Carton Dimensions (inches) Width
Length
Height
27
35
29½
     
Rough-in Dimensions (inches) Depth required to remove drawer

Height to top of waste
inlet

Vent outlet center distance from rear/left side

Waste inlet diameter (including flange)

Height to center or top of vent outlet assembly
44


30¾


12/11


3" DWV


21¾
     
Click on diagram to enlarge Centrex 1000 Rough-in
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.



Centrex 1000 NE Specifications

     
Composting Capacity Weekend & Vacation Use 4-6 people
     
Electrical Max Amps (with heater on)

Fan Watts (optional hookup)

Heater Watts (when thermostat switches it on)

Average Power Use in Watts (heater on ½ time)
NA

1.4 Watts

NA


NA
     
Unit Dimensions (inches) Height (unit only)
Depth (unit only)
Width (unit only)
Width required to turn handle
27½
26¼
31¼
35½
     
Vent and Drain Vent Pipe

Drain (hookup required for all uses)
4"

1"
     
Weights (lbs) Product Weight/ Shipping Weight
45/90
     
Shipping Carton Dimensions (inches) Width
Length
Height
27
35
29½
     
Rough-in Dimensions (inches)

 

Depth required to remove drawer

Height to top of waste
inlet

Vent outlet center distance from rear/left side

Waste inlet diameter (including flange)

Height to center or top of vent outlet assembly
44


30¾


12/11


3" DWV


31
     
Click on diagram to enlarge
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.



Centrex 1000 AC/DC Specifications

     
Composting Capacity Weekend & Vacation Use 5-7 or 4-6 people
     
Electrical Max Amps (with heater on)

Fan Watts (required or optional hookup)

Heater Watts (when thermostat switches it on)

Average Power Use in Watts (heater on ½ time)
3.3 or 0.28 Amps

30 required or 2.4 optional

350


200
     
Unit Dimensions (inches) Height (unit only)
Depth (unit only)
Width (unit only)
Width required to turn handle
28
27
45½
49
     
Vent and Drain Vent Pipe

Drain (hookup required for all uses)
2" and 4"

1"
     
Weights (lbs) Product Weight/ Shipping Weight
108/129
     
Shipping Carton Dimensions (inches) Width
Length
Height
28½
47
36
     
Rough-in Dimensions (inches) Depth required to remove drawer

Height to top of waste
inlet

Vent outlet center distance from rear/left side

Waste inlet diameter (including flange)

Height to center or top of vent outlet assembly
44


30¾


12/11


3" DWV


both 21¾ and 31
     
Click on diagram to enlarge
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.



Centrex 2000 Specifications

     
Composting Capacity Residential & Continuous Use

Weekend & Vacation Use
4-6 people

7-9 people
     
Electrical Max Amps (with heater on)

Fan Watts (required hookup)

Heater Watts (when thermostat switches it on)

Average Power Use in Watts (heater on ½ time)
3.6 Amps

30 Watts Required

370 Watts


200 Watts
     
Unit Dimensions (inches) Height
Depth
Width (unit only)
Width required to turn handle
28
27
45½
49
     
Vent and Drain Vent Pipe

Drain (hookup optional but recommended for heavy use)
2" Central Vac. Tubing

1"
     
Weights (lbs) Product Weight/ Shipping Weight
97/118
     
Shipping Carton Dimensions (inches) Width
Length
Height
28½
47
30
     
Rough-in Dimensions (inches) Depth required to remove drawer

Height to top of waste
inlet

Vent outlet center distance from rear/left side

Waste inlet diameter (including flange)

Height to center or top of vent outlet assembly
45


31


11/12


3" DWV


23½
     
Click on diagram to enlarge
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.



Centrex 2000 NE Specifications

     
Composting Capacity Residential & Continuous Use

Weekend & Vacation Use
3-5 people

6-8 people
     
Electrical Max Amps (with heater on)

Fan Watts (optional hookup)

Heater Watts (when thermostat switches it on)

Average Power Use in Watts
NA

1.4 Watts

NA


NA
     
Unit Dimensions (inches) Height
Depth
Width (unit only)
Width required to turn handle
26½
26½
45½
49
     
Vent and Drain Vent Pipe

Drain (hookup required for all uses)
4"

1"
     
Weights (lbs) Product Weight/ Shipping Weight
87/108
     
Shipping Carton Dimensions (inches) Width
Length
Height
28½
47
30
     
Rough-in Dimensions (inches) Depth required to remove drawer

Height to top of waste
inlet

Vent outlet center distance from rear/left side

Waste inlet diameter (including flange)

Height to center or top of vent outlet assembly
45


29½


11/12


3" DWV


32
     
Click on diagram to enlarge
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.



Centrex 2000 AC/DC Specifications

     
Composting Capacity Residential & Continuous Use

Weekend & Vacation Use
4-6 or 3-5 people

7-9 or 6-8 people
     
Electrical Max Amps (with heater on)

Fan Watts (required or optional hookup)

Heater Watts (when thermostat switches it on)

Average Power Use in Watts (heater on ½ time)
3.6 Amps or NA

30 Required or 2.4 Optional

370 or NA


200 or 3.4
     
Unit Dimensions (inches) Height
Depth
Width (unit only)
Width required to turn handle
28
27
45½
49
     
Vent and Drain Vent Pipe

Drain (hookup required for all uses)
2" Central Vac. Tubing

1"
     
Weights (lbs) Product Weight/ Shipping Weight
103/124
     
Shipping Carton Dimensions (inches) Width
Length
Height
28½
47
36
     
Rough-in Dimensions (inches) Depth required to remove drawer

Height to top of waste
inlet

Vent outlet center distance from rear/left side

Waste inlet diameter (including flange)

Height to center or top of vent outlet assembly
45


31


11/12


3" DWV


both 23½ and 32
     
Click on diagram to enlarge
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.


Centrex 3000 Specifications

     
Composting Capacity Residential & Continuous Use

Weekend & Vacation Use
6-8 people


10-12 people
     
Electrical Max Amps (with heater on)

Fan Watts (required hookup)

Heater Watts (when thermostat switches it on)

Average Power Use in Watts (heater on ½ time)
3.6 Amps

30 Watts Required

370 Watts


215 Watts
     
Unit Dimensions (inches) Height
Depth
Width (including collection housing 13½)
30¼
27½
71
     
Vent and Drain Vent Pipe


Drain (hookup required in all installations)
2" Central Vac. Tubing

1"
     
Weights (lbs) Product Weight/ Shipping Weight
102/172
     
Shipping Carton Box 1 Dimensions (inches) Width
Length
Height
28
61
33½
     
Shipping Carton Box 2 Dimensions (inches) Width
Length
Height
16
24
23
     
Rough-in Dimensions (inches) Depth required to remove drawer

Height to top of waste
inlet

Vent outlet center distance from rear/left side

Waste inlet diameter (including flange)

Height to center or top of vent outlet assembly
45½


32½


24/37¼


3" DWV


24¾
     
Click on diagram to enlarge
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.



Centrex 3000 NE Specifications

     
Composting Capacity Residential & Continuous Use

Weekend & Vacation Use
5-7 people


8-10 people
     
Electrical Max Amps (with heater on)

Fan Watts (optional hookup)

Heater Watts (when thermostat switches it on)

Average Power Use in Watts
NA

2.4 Watts

NA


NA
     
Unit Dimensions (inches) Height
Depth
Width (including collection housing 13½)
29¼
27½
71
     
Vent and Drain Vent Pipe

Drain (hookup required in all installations)
4"

1"
     
Weights (lbs) Product Weight/ Shipping Weight
88/164
     
Shipping Carton Box 1 Dimensions (inches) Width
Length
Height
28
60½
33
     
Shipping Carton Box 2 Dimensions (inches) Width
Length
Height
16
24
23
     
Rough-in Dimensions (inches) Depth required to remove drawer

Height to top of waste
inlet

Vent outlet center distance from rear/left side

Waste inlet diameter (including flange)

Height to center or top of vent outlet assembly
45½


31½


19¼/37¾


3" DWV


33 (top)
     
Click on diagram to enlarge
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.



Centrex 3000 AC/DC Specifications

     
Composting Capacity Residential & Continuous Use

Weekend & Vacation Use
7-8 or 5-6 people

10-12 or 8-10 people
     
Electrical Max Amps (with heater on)

Fan Watts (required or optional hookup)

Heater Watts (when thermostat switches it on)

Average Power Use in Watts (heater on ½ time)
3.6 Amps or NA

30 Required or 2.4 Optional

370 or NA


215 or 3.4
     
Unit Dimensions (inches) Height
Depth
Width (including collection housing 13½)
30¼
27½
71
     
Vent and Drain Vent Pipe

Drain (hookup required for all uses)
2" Central Vac. Tubing and 4"

1"
     
Weights (lbs) Product Weight/ Shipping Weight
107/194
     
Shipping Carton Box 1 Dimensions (inches) Width
Length
Height
28
61
37
     
Shipping Carton Box 2 Dimensions (inches) Width
Length
Height
16
24
23
     
Rough-in Dimensions (inches) Depth required to remove drawer

Height to top of waste
inlet

Vent outlet center distance from rear/left side

Waste inlet diameter (including flange)

Height to center or top of vent outlet assembly
45½


32½


Both 24/37¾ and 19¼/37¾

3" DWV


both 24¾ and 33
     
Click on diagram to enlarge
Requires Adobe Reader to open enlarged diagram. If you don't have Adobe Reader, click on the Adobe icon to download a free copy.


© 2005-2016 LetsGoGreen.com ~ All Rights Reserved ~ Enjoy Indoor Convenience With A Composting Toilet